David – Photovoltaic System
David – Photovoltaic System
General Information | |
---|---|
Location: | Mooiplaats, Pretoria, Gauteng, South Africa |
Dwelling: | 3 Bedroom domestic house |
Backup Power: | VAC Solar was tasked to totally reinstall and service the existing faulty PV system. Batteries are to be replaced with a LiFePO4 battery once the existing deep cycle batteries reaches end of life. |
Technical Information | |
System Type: | Bi-Directional |
Total System Size: | 7.2kWp |
Inverter: | 10kW Pure Sine Wave Microcare Bi-Directional Inverter |
MPPT: | 2x 150/100 Microcare MPPT Charge Controllers |
PV Modules: | 15x 240Wp Polycrystalline PV Modules - East |
15x 240Wp Polycrystalline PV Modules - West | |
PV Module Mounting: | LM-TBR-V Short Rails, Landscape Mounting on an IBR Roof |
Battery Type: | Microcare Battery Monitor |
HMI: | |
Protection: | Earthing |
DC - Fuses and Surge Arrestors (2x 5 String Low Voltage Combiner Boxes) | |