    David – Photovoltaic System

    General Information
     

    Location:

    Mooiplaats, Pretoria, Gauteng, South Africa

    Dwelling:

    3 Bedroom domestic house

    Backup Power:

    VAC Solar was tasked to totally reinstall and service the existing faulty PV system. Batteries are to be replaced with a LiFePO4 battery once the existing deep cycle batteries reaches end of life.

    Technical Information

    System Type:

    Bi-Directional

    Total System Size:

    7.2kWp

    Inverter:

    10kW Pure Sine Wave Microcare Bi-Directional Inverter

    MPPT:

    2x 150/100 Microcare MPPT Charge Controllers

    PV Modules:

    15x 240Wp Polycrystalline PV Modules - East

    15x 240Wp Polycrystalline PV Modules - West

    PV Module Mounting:

    LM-TBR-V Short Rails, Landscape Mounting on an IBR Roof

    Battery Type:

    Microcare Battery Monitor

    HMI:

    Protection:

    Earthing

    DC - Fuses and Surge Arrestors (2x 5 String Low Voltage Combiner Boxes)